HPLC Method Development, Tips & Troubleshooting
/
/
/

  • Access practical guidance for HPLC and LC-MS method development, troubleshooting, column care, mobile phase optimization, and chromatographic performance improvement. Explore real-world solutions, best practices, and technical insights to improve analytical results and laboratory efficiency.

    • Method development guidance

    • LC-MS optimization

    • Mobile phase selection

    • Column care and recovery

    • Peak shape troubleshooting

    • Retention troubleshooting

    • HILIC and ANP strategy

    • Sample preparation advice

    • Instrument performance guidance

    • Real-world chromatography problem solving


Bromhexine HPLC Method Development - Tech Information
Read More
Acetone as a Mobile Phase Solvent in HILIC Methods - Tech Information
Read More
Acetone as The Organic Mobile Phase Component - AppNote
Read More
Acid Concentration Optimization in HILIC Methods Using Cogent TYPE-C Columns - Tech Information
Read More
Activity of a Stationary Phase in Chromatography Definition and Impact on HPLC Separations - Tech Information
Read More
Adsorption of Analytes Occurs Rapidly in Autosampler Vials – AppNote
Read More
Amide vs Amino HPLC Columns Differences in Stability Selectivity and Performance - Tech Information
Read More
Ammonium Acetate and Ammonium Formate in Acetonitrile Rich HILIC Mobile Phases - Tech Information
Read More
Ammonium Acetate in LC-MS Methods Preventing Source Contamination and Signal Loss - Tech Information
Read More
Ammonium Acetate or Ammonium Formate in Diamond Hydride Methods - Tips and Suggestions
Read More
Ammonium Acetate or Triethylamine TEA Use with Cogent HPLC Columns - Tips and Suggestions
Read More
Ammonium Acetate Use in HILIC LC-MS Methods with TYPE-C Columns - Tech Information
Read More
Ammonium Fluoride in HILIC HPLC and LC-MS Methods Using TYPE-C Columns - Tech Information
Read More
Analyte Recovery Changes Between Days a Case Study - Tech Information
Read More
Autoclaving Glass Inserts with Plastic Spring is Not Recommended - Tech Information
Read More
Autosampler Vial Diameter Specifications and Autosampler Compatibility - Tech Information
Read More
Avoid Contamination of Mobile Phases While Using Sparging Stone - Tips & Suggestions
Read More
Avoid Distorted Peak Shapes When Using a Basic Mobile Phase pH for the Analysis of a Lipophilic Amine - Tips & Suggestions
Read More
Avoid Ion Suppression in LC-MS When Ion-Pair Reagents Are Traditionally Required - HPLC Primer
Read More
Avoid Spurious Peaks from Nylon Syringe Filters When Using Electrochemical Detection - Tech Information
Read More
Back Flushing an HPLC Column Risks and Benefits - Tech Information
Read More
Backflushing is Not Recommended for Column Filters - Tech Information
Read More
Baseline Drift and UV Trace Slope in Gradient HPLC Methods - Tech Information
Read More
Baseline Noise with Cogent Diamond Hydride HPLC column - Tech Information
Read More
Baseline Stability in HILIC Methods Using Cogent Diamond Hydride Columns - Tech Information
Read More
Blockage Minimization in HPLC Columns - HPLC Primer
Read More
Blocked HPLC Column May be Recovered - Tips & Suggestions
Read More
Broad and Asymmetrical Peak Troubleshooting in Reversed-Phase LC-MS Methods - Tech Information
Read More
Broad or Split Peaks in HILIC When Using Methanol ‑ Rich Diluents - Tips and Suggestions
Read More
Bubble Point Pressure and Filtering Water Through Hydrophobic Membranes - Tech Information
Read More
Buffer Concentration Effects on Acid Retention in HILIC Methods Using TYPE-C™ Columns - Tech Information
Read More
Calculating the Internal Volume of Laboratory Tubing - Tech Information
Read More
Capsaicinoids in Hot Sauce Analysis by HPLC - Tips and Suggestions
Read More
Capsaicinoids Separation in Hot Sauce Extracts by HPLC and LC-MS - AppNote
Read More
Carotene or Lycopene - Column Suggestions - Tips and Suggestions
Read More
Changing Mobile Phases with Acids to One with Ammonium Salts. Tips & Suggestions
Read More
Changing Retention Times and a Spurious Peak with a Silica-C column - Troubleshooting
Read More
Choose an Appropriate Re-Equilibration or Post Time for Gradient HPLC - HPLC Primer
Read More
Choosing Mobile Phase Additives for Negative Ionization LC-MS Methods - Tech Information
Read More
Clean or Washing HPLC Column For Extended Useful Lifetime - Tech Information
Read More
Clean Sparging Stones and Inline SS Filters - How To
Read More
Cleaning Cogent Diamond Hydride Columns After Blood Sample Analysis - Tech Information
Read More
Cleaning Cogent TYPE-C HPLC Columns - Tips and Suggestions
Read More
Cleaning Plasma Samples from Cogent TYPE-C HPLC Columns - Tips and Suggestions
Read More
Cleaning Process Not Recommended with RSA Autosampler Vials - Tech Information
Read More
Cocaine and Polar Metabolites ( Ecgonine) Separation using LC‑MS / MS - Tips and Suggestions
Read More
Column Cleaning and Care in UHPLC Columns - Tips & Suggestions
Read More
Column Filter Compatibility Guide - Tech Information
Read More
Column Particle Damage as a Cause of Frit Blockage and Elevated HPLC Backpressure - Tech Information
Read More
Column Void Volume and Capacity Factor Calculations for HPLC Method Transfer - Tech Information
Read More
Common Sources of Variability in Analytical Sample Preparation - Tech Information
Read More
Comparing Column Efficiency Between 4 um and 2.2 um HPLC Columns - Tech Information
Read More
Conditioning Procedure for a New Diamond Hydride HPLC Column - Tech Information
Read More
Connecting Guard Column Holders to Analytical Columns - Tech Information
Read More
Constant Pressure Method on two Instruments Producing Different Flow Rates- Troubleshooting
Read More
Convert HPLC Columns Between Reversed Phase and Normal Phase - How to
Read More
Converting 0.1% w/v Ammonium Acetate to Millimolar Concentration for HPLC and LC-MS - Tech Information
Read More
Correct LC-MS Ion for Quaternary Amine Analysis - Tech Information
Read More
Crimped Cap Removal from Fused Insert Vials Without Damaging the Insert - Tech Information
Read More
Degradation of Samples Due to Hydrolysis on HPLC Columns - HPLC Primer
Read More
Detector Response Improvement in HPLC UV Detectors - Tech Information
Read More
Effects of Flow Rate on Peak Area Response Decline in HPLC UV Detection - Tech Information
Read More
Effects of Mobile Phase Ionic Strength in HILIC Methods Using Cogent TYPE-C Columns - Tech Information
Read More
Effects of Washing and Reusing Autosampler Vials on Sample Recovery and Contamination Risk - Tech Information
Read More
Eliminating High Background Noise in New Cogent HPLC Columns - Tips and Suggestions
Read More
Eliminating Retention Time Drift in LC-MS HILIC Methods Using Diamond Hydride Columns - Tech Information
Read More
Eliminating Shoulder Peaks in HPLC Using C18 Columns - Tech Information
Read More
Equilibration Practices to Protect HPLC Column Performance - Tech Information
Read More
Establishing Linearity for HPLC Analytical Methods - Tech Information
Read More
Evaluating Suspected Outliers in HPLC Data Sets Using Q Test - Tech Information
Read More
Extra Peaks When Not Using the Same Syringe Filter - Troubleshooting
Read More
Filtering HPLC Solvents and Buffers Before Use - FAQ
Read More
Fittings Choice 1 piece fitting or a 2 piece fitting for HPLC - HPLC Primer
Read More
Fittings Recommended for Mobile Phase Connections - HPLC Primer
Read More
Flat Baselines in Gradient HPLC Without Blank Subtraction - Tech Information
Read More
Formic Acid Improves Peak Shapes Retention and Carryover for Polar Compounds with the Cogent Diamond Hydride HPLC Column - Tips & Suggestions
Read More
Fosetyl Aluminum Analysis by HPLC - Tech Information
Read More
Fosetyl Aluminum Analysis Using a Bidentate C18 Column - Tips and Suggestions
Read More
Glutamine Glutamic Acid and Aspartic Acid Separation - Tech Information
Read More
Gradient Method Adjustments When Changing HPLC Column Internal Diameter - Tech Information
Read More
High HPLC System Pressure Originating from the Pump Module Troubleshooting - Tech Information
Read More
High Injection Volume Effect on Column Performance in HILIC Methods - Tech Information
Read More
High Pressure Develops after Flushing a Cogent Diamond Hydride HPLC Column with Acetonitrile Cause and Solution - Tech Information
Read More
HILIC Column Robustness and the Advantages of TYPE-C Technology - Tech Information
Read More
HILIC Methods Using Cogent TYPE-C Columns Compared to Conventional HILIC Columns - Tech Information
Read More
HILIC Separations of Polar Compounds Using TYPE-C Columns - Tech Information
Read More
Holmium Oxide and Caffeine Standards for UV-Vis and HPLC Detector Qualification Below 230 nm - Tech Information
Read More
Holmium Oxide for HPLC UV Detector Performance Qualification - Tips and Suggestions
Read More
How Pulsations from an HPLC Pump Can Impact Column Performance - Tech Information
Read More
How Tight Should an Autosampler Vial Cap Be to Prevent Septa Push-Through During Injection - Tech Information
Read More
How to keep HPLC columns free of adsorbed Preventing Contaminant Buildup and Maintaining HPLC Column Performance - Tech Informationcontaminants - How To
Read More
HPLC and LC-MS Method Validation Fundamentals for Regulated Laboratories - Tech Information
Read More
HPLC Columns You May Not Know About That Can Be Very Helpful - White Paper
Read More
HPLC Method Transferred to Near UHPLC - AppNote
Read More
HPLC Qualification Kits Compatible with Virtually All HPLC Systems - Tech Information
Read More
Improve LOD or Detection Limits in HPLC - Tech Information
Read More
Improving Accuracy and Precision for Polar Compound Analysis Using HILIC Methods and TYPE-C Columns - Tech Information
Read More
Improving Citric Acid Retention and Peak Shape Reproducibility in LC-MS Analysis - Tech Information
Read More
Improving Cysteine and Cystine Analysis in LC-MS Applications - Tech Information
Read More
Improving LC-MS Sensitivity for Sugars Using Sodium Adduct Formation - Tech Information
Read More
Improving LC-MS Sensitivity with HILIC Methods for Polar Compound Analysis - Tech Information
Read More
Improving Metformin Reproducibility and Peak Shape in Plasma Sample Analysis - Tech Information
Read More
Improving Peak Shape and Retention for Organic Acids in HILIC Methods Using Cogent Diamond Hydride Columns - Tech Information
Read More
Improving Peak Shape for Phosphorylated Compounds in HILIC Methods Using TYPE-C Columns - Tech Information
Read More
Improving Peak Shape in HILIC Methods - Tech Information
Read More
Improving Polar Compound Analysis with TYPE-C HILIC Columns for LC and LC-MS - Tech Information
Read More
Improving Retention and Peak Shape Reproducibility for Citric Acid Analysis - Tech Information
Read More
Improving Separation of Two Peaks in Reversed Phase HPLC - Tips and Suggestions
Read More
Increasing Selectivity and Resolution for a Xylose and Ribose HPLC Method Resolution - Tips and Suggestions
Read More
Injection Guidance for Cogent TYPE-C HPLC Columns - Tips and Suggestions
Read More
Injection Techniques for Aqueous Samples in HILIC Methods - Tech Information
Read More
Inorganic Buffers Use for HPLC UV Analysis of Citric Acid - Tips & Suggestions
Read More
Intermittent Pressure Spikes in HPLC Systems and How to Troubleshoot Them - Tech Information
Read More
Internal Diameter for HPLC Mobile Phase Delivery - Tech Information
Read More
Ion‑Pairing Reagents with Cogent Diamond Hydride Columns - Tech Information
Read More
L3 Linearity Solution to Assess UV-Visible Detector Wavelength Accuracy - Tech Information
Read More
LC-MS Challenges Associated with High-Salt HILIC Mobile Phases - Tech Information
Read More
Limited Volume Vial Selection Suggestions - Tech Information
Read More
Linear Flow and Pressure Testing to Evaluate HPLC Column Performance - Tech Information
Read More
Lisinopril Assay Results Calculation Using a Dihydrate Reference Standard - Tech Information
Read More
Litchi Seed Extracts Analyzed by LC-MS - AppNote
Read More
LOQ and LOD Differences Between Instruments - Tech Information
Read More
Low pH buffers Used to Separate Acidic Compounds in RP - HPLC Primer
Read More
Low Volume Sample Study of Proteins Recommendation - Tech Information
Read More
Lower Retention When Functional Group in a Compound Should be Ionized - Troubleshooting Tips
Read More
Maleic Hydrazide Method Development - Tips & Suggestions
Read More
Managing PFAS and Trace Contamination Sources in Chromatographic Analysis - Tech Information
Read More
Matching Guard Column ID to Prep Column ID for Optimal Performance - Tips and Suggestions
Read More
Maximum Operating Pressure Ratings for Cogent HPLC Columns by Particle Size - Tech Information
Read More
Maximum Pressure Cogent HPLC Columns Can Tolerate - Tech Information
Read More
Maximum Recommended Flow Rates for Different Filter Pore Sizes – Tech Information
Read More
Maximum Salt Concentration Recommendations for Cogent TYPE-C HPLC Columns - Tech Information
Read More
Membrane Choice in Syringe Filters for Aqueous Buffers - Tech Information
Read More
Metal Content Affects Silica Particle and Contributes to Peak Shape - Tech Information
Read More
Methacrylic Acid and Dodecyl Benzene Sulfonic Acid Analysis - Tips and Suggestions
Read More
Methanol in Place of Acetonitrile in HPLC Methods - Tech Information
Read More
Method Development Advice for Using a TYPE-C HPLC Column - Tips and Suggestions
Read More
Microbial Growth Prevention in HPLC Mobile Phases - Tech Information
Read More
MRQ and Max Recovery Autosampler Vials Functional Differences and Selection Considerations - Tech Information
Read More
Negative Baselines and Baseline Drift in Gradient HPLC Methods - Tech Information
Read More
Negative Baselines Observed at 214 nm During Gradient HPLC Methods - Tech Information
Read More
No Peaks Observed for Succinic Acid or Alpha-Ketoglutarate in LC-MS Using a Cogent Diamond Hydride Column - Tech Information
Read More
Normal Phase HPLC Syringe Filter Recommendation - Tech Information
Read More
PEEK or Stainless Steel for HPLC Column Hardware - Tips and Suggestions
Read More
PFAS Analysis Selecting Glass or Polypropylene Vials for Sampling, Storage and LC-MS Analysis - Tech Information
Read More
Phosphate Precipitation Risks in HPLC Columns - HPLC Primer
Read More
Phospholipids Analyzed with LCMS - AppNote
Read More
Polar Compound Method Development Using Cogent TYPE-C HILIC Columns - Tech Information
Read More
Positional Isomer Separations by HPLC and LC-MS Using Cogent Columns - Tech Information
Read More
Positive and Negative Ion Mode Mobile Phase Additives for LC-MS Method Development - Tech Information
Read More
Positive Ion Mode LCMS Retention of Polar Compounds - Tips and Suggestions
Read More
Post Time in HPLC and LC-MS Gradient Methods - Tech Information
Read More
Pre Slit Septa in Autosampler Vial Cap - Purpose - HPLC Primer
Read More
Precision and Suitability of the Cogent TYPE-C HPLC Columns in LCMS - Tech Information
Read More
Preparative Chromatography Benefits Using TYPE-C Columns - Tips and Suggestions
Read More
Preparing 10 mM Ammonium Acetate Mobile Phases in High-Acetonitrile HILIC Methods - Tech Information
Read More
Preparing a 16 mM Ammonium Acetate Mobile Phase in 90 10 Acetonitrile Water for HPLC and LC-MS - How To
Read More
Preparing Premixed Diluents to Improve Accuracy in HPLC Sample Preparation - Tech Information
Read More
Pressure Expected When Using a Diamond Hydride 2.o UHPLC Column - Tech Information
Read More
Pressure Increase at a Lower Flow Rate - HPLC Primer
Read More
Pressure Shock and Rapid Backpressure Changes in HPLC Columns - Tech Information
Read More
Proper Storage Procedures for Cogent RP and Cogent HPS HPLC Columns - Tech Information
Read More
Protect HPLC Columns from Permanently Adsorbed Compounds - HPLC Primer
Read More
Proteins Filtration – Choosing the Right Membrane - HPLC Primer
Read More
Purge Metals from HPLC System Using EDTA - How To
Read More
Quaternium-15 Isomer Separation on Cogent Diamond Hydride Columns - Tech Information
Read More
Recovering an HPLC Column After Ammonium Acetate Precipitation - Tech Information
Read More
Removing a Stuck Ferrule from an HPLC System or Column - Tech Information
Read More
Repair a Blocked Frit in an HPLC column - Tips and Suggestions
Read More
Rescaling Residual Graphs in HPLC Qualification Kit Excel Templates - Tech Information
Read More
Restoring the Initial Method Results Analyzing AMP ADP ATP UDP and GPT in Biological Extracts - Troubleshooting
Read More
Retaining Polar Compounds with Cogent Bidentate C18 Columns Reversed Phase and HILIC Considerations - Tech Information
Read More
Retention of Ionized Polar Compounds in HILIC Methods Using Cogent TYPE-C Columns - Tech Information
Read More
Retention Time Differences Between HPLC Systems - Tech Information
Read More
Retention Time Variability Caused by Mobile Phase Mixing Inconsistencies in HPLC Systems - Tech Information
Read More
Retention Times Changes with Mobile Phase Storage Effects on Retention Time and Peak Shape in HPLC Methods - Tech Information
Read More
Ribose and Xylose Analysis Using Amide HILIC Columns Without Schiff Base Formation - AppNote
Read More
RSA-Pro X Autosampler Vial Improves Quantitation Precision – AppNote
Read More
Sample Carry Over Using One Syringe Filter for Many Samples - HPLC Primer
Read More
Sample Concentration Effects on Retention Time in HPLC Analysis - Tech Information
Read More
Sample Diluent Mismatch as a Cause of Poor HPLC Peak Shape - Tech Information
Read More
Sample Diluents Should Match Your Starting Mobile Phase - Tech Information
Read More
Sample Loading Capacity and Injection Volume Guidelines for Semi-Preparative Cogent TYPE-C HPLC Columns - Tech Information
Read More
Saw Tooth UV Baselines Caused by Immiscible Solvents in HPLC Columns - Tech Information
Read More
Screw Thread Call Outs for HPLC Fittings and Autosampler Caps - Tech Information
Read More
Selecting Organic Solvents for HILIC Methods Using Cogent TYPE-C Columns - Tech Information
Read More
Selecting the Appropriate Guard Column for Cogent HPLC Columns - Tech Information
Read More
Selectivity Modification in an HILIC Method Using Different Mobile Phase pH - Tips & Suggestions
Read More
Sensitivity and Signal-to-Noise Ratio in HPLC - Tech Information
Read More
Separate Phospholipids with HPLC – Practical - Tips and Suggestions
Read More
Separating Hydrophilic and Hydrophobic Compounds in the Same HILIC Method - Tech Information
Read More
Separating Polar and Non-Polar Compounds with Cogent TYPE-C Silica Columns
Read More
Separation of Phenylephrine HCl Acetaminophen and Dextromethorphan - Tips and Suggestions
Read More
Serum Sample Analysis Using Cogent Diamond Hydride Columns for LC-MS - Tech Information
Read More
Sodium and Ammonium Adduct Formation for Improved Sugar Detection in LC-MS - Tech Information
Read More
Sodium Ions and Sodium Succinate Analysis in HILIC Methods Using Cogent TYPE-C Columns - Tech Information
Read More
Split Peaks and High Back Pressure in HPLC Analyses - Troubleshooting
Read More
Starting Flow Rate Guidelines for Common HPLC Column Internal Diameters - Tech Information
Read More
Storage Conditioning and Solvent Transition Guidelines for Cogent TYPE-C HPLC Columns - Tech Information
Read More
Storage of HSQ and PQ Qualification Kit Solutions - Tech Information
Read More
Storing, Conditioning, and Maintaining Cogent Diamond Hydride HPLC Columns - Tech Information
Read More
Switching Between Reversed Phase and Normal Phase Methods on Cogent TYPE C Silica Columns - Tech Information
Read More
System Pressure Considerations When Using 90% Methanol and 10% Water with Cogent TYPE-C HPLC Columns - Tech Information
Read More
Tandem HPLC Columns in One Separation for Polar and Non Polar Compounds - Tips and Suggestions
Read More
Tartaric and Malic Acid Separation in Complex Organic Acid Mixtures Using HILIC LC-MS- AppNote
Read More
Temperature and Pressure Limits for Amber Glass Autosampler Vials - Tech Information
Read More
Temperature Control Considerations for Cogent UDC-Cholesterol Columns - Tech Information
Read More
Temperature Operating Range of MICROSOLV Polypropylene Autosampler Screw Caps - Tech Information
Read More
Temperature Range Maximum for Cogent Diamond Hydride HPLC Columns - Tech Information
Read More
Tighten Screw Caps Properly - Tech Information
Read More
Triethylamine TEA with a Cogent Silica-C Column - Tech Information
Read More
Troubleshooting Diminished Peak Height in Biological Extract Analysis Using Cogent Diamond Hydride Columns - Tech Information
Read More
Troubleshooting Poor HPLC Results Before Suspecting the Column - Tech Information
Read More
Two Peaks for Quaternium-15 or Dowicil-75 in LCMS Data - Tech Information
Read More
Understanding Nominal Particle Size Differences in 4 µm vs 5 µm C18 Columns - HPLC Primer
Read More
Understanding Polar Compound Retention Why LFER Models Often Provide More Insight Than Log D - Tech Information
Read More
Understanding Retention Decreases as Water Content Increases on Cogent Bidentate C18 Columns - Tech Information
Read More
Understanding the Impact of Extra Column Volume on HPLC Method Performance - Tech Information
Read More
Understanding the Master Batch Process for Cogent TYPE-C HPLC Columns - Tech Information
Read More
Use Trifluoroacetic Acid TFA to Improve the Performance in LC-MS - FAQ
Read More
Using EDTA in Mobile Phases to Improve Peak Shape for Metal-Sensitive Compounds - Tech Information
Read More
Using Isopropanol IPA in HILIC Mobile Phases with Cogent TYPE-C Columns - Tech Information
Read More
Using Silica or Silica‑C Guard Columns with Analytical Columns of Different Phases - HPLC Primer
Read More
Using Triethylamine TEA in HILIC Methods for Simple Sugar Analysis - Tech Information
Read More
USP Chapter 621 Allowed Adjustments to Chromatographic Methods and Method Modernization - Tech Information
Read More