Category: HPLC Tips and Suggestions
/
/
/
Bromhexine HPLC Method Development - Tips and Suggestions
Read More
10mM Ammonium Acetate Buffer 90:10 in Acetonitrile Preparation for HPLC and LCMS - Tips & Suggestions
Read More
Acetone as a Mobile Phase Solvent in Aqueous Normal Phase - ANP - Tech Information
Read More
Acetone as The Organic Mobile Phase Component - AppNote
Read More
Activity Term in Chromatography Defined - HPLC Primer
Read More
Add 10 micro molar EDTA to Mobile Phase for Better Peak Shapes - Tips & Suggestions
Read More
Adsorption of Analytes Occurs Rapidly in Autosampler Vials – AppNote
Read More
Allowed Adjustments to USP Methods - Tips & Suggestions
Read More
Amide or Amino HPLC Columns What are the Differences - Tech Information
Read More
Ammonium Acetate 0.1% w/v Molarity - HPLC Primer
Read More
Ammonium Acetate in LCMS Requires Attention to Cleaning - Tips & Suggestions
Read More
Ammonium Acetate or Formate in an Acetonitrile Based Mobile Phase - Tips & Suggestions
Read More
Ammonium Acetate or Triethylamine TEA Use with Cogent HPLC Columns - Tips and Suggestions
Read More
Ammonium Acetate Use in ANP with LCMS - Tips and Suggestions
Read More
Analyzing metformin in plasma samples how do I obtain reproducible results and peak shapes - FAQ
Read More
Aqueous Normal Phase ANP and How it is Useful for Polar Compound Separation - Tech Information
Read More
Aqueous Normal Phase ANP HPLC Methods Better to Use Than HILIC Methods - Tech Information
Read More
Autoclaving Glass Inserts with Plastic Spring is Not Recommended - Tech Information
Read More
Avoid Ion Suppression Issues in LCMS if You Need to Use an Ion-Pair Agent - HPLC Primer
Read More
Avoid microbial growth in HPLC mobile phases - How to
Read More
Avoid Spurious Peaks from Nylon Syringe Filters with DI Water Using Electrochemical Detection - Tips & Suggestions
Read More
Back Flush and Wash an HPLC Column for Reuse - Tips & Suggestions
Read More
Back Flushing an HPLC Column Risks and Benefits - Tech Information
Read More
Base Deactivated HPLC Column Definition - HPLC Primer
Read More
Baseline Noise with Cogent Diamond Hydride HPLC column - Tips and Suggestions
Read More
Baseline Problems in ANP Methods with the Cogent Diamond Hydride Column - Tips and Suggestions
Read More
Better Methods Than HILIC for Polar Compound Analysis in HPLC and LC‑MS - Tips & Suggestions
Read More
Better separation of two peaks for Reversed Phase RP HPLC - Tips & Suggestions
Read More
Biological Extracts - Troubleshooting for Diminished Peak Height Using Cogent Diamond Hydride™ Columns - Tech Information
Read More
Blocked HPLC Column May be Recovered - Tips & Suggestions
Read More
Broad or Split Peaks in ANP When Using Methanol ‑ Rich Diluents - Tips and Suggestions
Read More
Broad Peaks That are Non Symmetrical in LCMS in Reversed Phase Solutions - Troubleshooting
Read More
Bubbling or fizzing coming from a new Cogent TYPE-C column - Tech Information
Read More
Buffer Concentration can Affect ANP Retention of Acids in HPLC Analyses - Tips and Suggestions
Read More
Calculate assay of lisinopril dihydrate based on the anhydrous form - How to
Read More
Calculate The Internal Volume of a Tube - How to
Read More
Can I use a silica or Silica-C guard column with an analytical column of a different phase - FAQ
Read More
Can I use triethylamine TEA with a Cogent Silica-C column - FAQ
Read More
Can I Use Trifluoroacetic Acid TFA to Improve the Performance in LCMS - FAQ
Read More
Can rapid changes in column back pressure damage an HPLC column - FAQ
Read More
Capsaicinoids Separation in Hot Sauce by HPLC - Tips & Suggestions
Read More
Carotene or Lycopene Column Suggestions - FAQ
Read More
Changing Column ID Means You Must Change your Gradient - Tips & Suggestions
Read More
Changing in the Mobile Phase with Acids to One with Ammonium Salts. Tips & Suggestions
Read More
Check for High Pressure Traced to the HPLC Pump Module - Tips & Suggestions
Read More
Choose a Suitable Mobile Phase Additive for Negative Ionization Mode in LCMS - Tips & Suggestions
Read More
Choose an Appropriate Re-Equilibration or Post Time for Gradient HPLC - How To
Read More
Citric acid retention and peak shape has changed compared to data from a previous run what happened - FAQ
Read More
Cleaning Cogent TYPE-C Silica Based HPLC Columns - Tips and Suggestions
Read More
Cleaning HPLC Columns After or Before Use - HPLC Primer
Read More
Cleaning Process Not Recommended with RSA Autosampler Vials - Tech Information
Read More
Cleaning SOP for Cogent Diamond Hydride When Using Blood Samples - Tips and Suggestions
Read More
Cocaine and Polar Metabolites ( Ecgonine) Separation using LC‑MS / MS - Tips and Suggestions
Read More
Cogent Column Disposable Filter Compatibility Guide - Tech Information
Read More
Cogent Column Filter Backflushing is Not Recommended - Tech Information
Read More
Cogent TYPE-C Columns Used in Prep Chromatography Offers Value - Tips & Suggestions
Read More
Column Cleaning and Care in UHPLC Columns - Tips & Suggestions
Read More
Conditioning Procedure for a New Diamond Hydride HPLC Column - Tech Information
Read More
Contaminants including PFAS leaching into an analysis - Tips & Suggestions
Read More
Convert HPLC Columns Between Reversed Phase and Normal Phase - How to
Read More
Crimped Cap Removal from Fused Insert Vials Without Damaging the Insert - Tech Information
Read More
Cut PEEK tubing using a Clean Cut90 cutter - How to
Read More
Cut stainless steel tubing for HPLC properly - How to
Read More
Cysteine analysis tips for LCMS - Tips & Suggestions
Read More
Degradation of Samples Due to Hydrolysis on HPLC Columns - HPLC Primer
Read More
Determining Efficiency of HPLC Methods Comparing 4um v 2.o HPLC Columns - HPLC Primer
Read More
Difference Between a 4um and a 5um Particle in a C18 Column - Tech Information
Read More
Do You Really Need High pH for Retention in HPLC - Tips & Suggestions
Read More
Drawbacks in terms of robustness for HILIC columns - Tips and Suggestions
Read More
Effects of Washing and Re-using Autosampler Vials on Sample Loss and Contamination - Tech Information
Read More
Eliminate High Background Noise Using a New Cogent HPLC Column - Tips & Suggestions
Read More
Eliminate Retention Time Drift in LCMS With Aqueous Normal Phase ANP Methods - Tips & Suggestions
Read More
Eliminating Shoulder Peaks in an HPLC Method Using Cogent RP C18 Columns - Tips & Suggestions
Read More
Equilibrating HPLC Column Suggestions to Protect the Columns - Tips & Suggestions
Read More
Factors that affect sensitivity in HPLC - Tech Information
Read More
For Normal Phase HPLC which syringe filter do you recommend - FAQ
Read More
For Sugars Analyzed by LCMS Sodium Acetate is recommended for Sensitivity of Na Adducts - Tips & Suggestions
Read More
For the separation of polar intermediates in reversed phase HPLC which C18 column do you recommend - FAQ
Read More
Formic Acid Improves Peak Shapes Retention and Carryover for Polar Compounds With the Cogent Diamond Hydride HPLC Column - Tips & Suggestions
Read More
Fosetyl Aluminum Analysis by HPLC - Tips & Suggestions
Read More
Fosetyl aluminum analysis by Reversed Phase HPLC Bidentate C18 - Tips & Suggestions
Read More
Guard Column Suggestions With a Larger ID or Prep Columns - Tips & Suggestions
Read More
High Pressure Develops after Flushing a Cogent Diamond Hydride HPLC Column with Acetonitrile Cause and Solution - FAQ
Read More
High‑Molecular‑Weight Compounds Fail to Retain on the Cogent Diamond Hydride Column — and the Correct Column to Use - Tips and Suggestions
Read More
Holmium Oxide for HPLC UV Detector Performance Qualification - Tips and Suggestions
Read More
How Can I Fix Poor Peak Shape for Phosphorylated Compounds in Aqueous Normal Phase ANP Methods - Tips & Suggestions
Read More
How can I fix split peaks with high back pressure in HPLC analyses - FAQ
Read More
How can I improve accuracy and precision when separating polar compounds by HPLC using Aqueous Normal Phase ANP - FAQ
Read More
How can I separate capsaicinoids in hot sauce by HPLC - Tips & Suggestions
Read More
How Can I Separate Methacrylic Acid and Dodecyl Benzene Sulfonic Acid - Tips & Suggestions
Read More
How do I Avoid Distorted Peak Shapes When Using a Basic Mobile Phase pH for the Analysis of a Lipophilic Amine - Tips & Suggestions
Read More
How Does Ammonium Fluoride Affect HPLC and LCMS Data if using Aqueous Normal Phase ANP Methods - HPLC Primer
Read More
How Pulsations from an HPLC Pump Can Impact Column Performance - Tech Information
Read More
How Tight Should an Autosampler Vial Cap be to Prevent Push Through of the Septa During Injection - HPLC Primer
Read More
How to calculate key data in HPLC - INTERNAL ONLY
Read More
How to calibrate UV-vis and HPLC detectors with NIST traceable solutions below 230nm - Tips & Suggestions
Read More
How to Choose an Appropriate Guard Column When Using a Cogent Column - Tips & Suggestions
Read More
How to clean sparging stones and In line SS filters - Tips & Suggestions
Read More
How to Condition Cogent RP or HPS Columns for Storage - Tips & Suggestions
Read More
How to Get Improved Retention and Peak Shape for Glutamine Glutamic Acid and Aspartic Acid - Tips & Suggestions
Read More
How to handle sparging stones to avoid contamination of mobile phases - Tips & Suggestions
Read More
How to improve LOD or detection limits in HPLC - Tips & Suggestions
Read More
How to keep HPLC columns free of adsorbed contaminants - How To
Read More
How to repair a blocked frit in an HPLC column - Tips & Suggestions
Read More
How to Tighten Screw Caps Properly - HPLC Primer
Read More
HPLC Columns You May Not Know About That Can Be Very Helpful - White Paper
Read More
HPLC Method Linearity Accuracy - Tips & Suggestions
Read More
HPLC stationary phase can be responsible for a blocked frit- Tips & Suggestions
Read More
Hydrophilic and Hydrophobic Molecules Separation in the Same Aqueous Normal Phase ANP Method - Tips & Suggestions
Read More
I see a strange saw tooth type of pattern in the UV baseline using my Cogent HPLC column what is it and how can I fix it - FAQ
Read More
I See Extra Peaks When I am Not Using the Same Syringe Filter - Tips & Suggestions
Read More
If I do not remove gas from my mobile phase solvents what are the consequences - FAQ
Read More
Improve or obtain flat baselines in HPLC methods with a gradient - Tips & Suggestions
Read More
Improvement in signal to noise in LCMS with an ANP method - Tips & Suggestions
Read More
Improving peak shapes in an HPLC method in Aqueous Normal Phase ANP - Tips & Suggestions
Read More
Increasing Selectivity and Resolution for a Xylose and Ribose HPLC Method Resolution - Tips & Suggestions
Read More
Injection Guidance for Cogent TYPE-C HPLC Columns - Tips and Suggestions
Read More
Injection Technique for Aqueous Samples in Water using in ANP - Tips and Suggestions
Read More
Inorganic Buffers Use for HPLC UV Analysis of Citric Acid - Tips & Suggestions
Read More
Integrate a peak with a shoulder - How to
Read More
Ion‑Pairing Reagents with Cogent Diamond Hydride Columns - Tech Information
Read More
Issues with a steep UV trace slope in gradient HPLC methods - Tips & Suggestions
Read More
Keep Surface Treated Frits From Biofouling - Tips & Suggestions
Read More
Know the void volume of an HPLC column - Tips & Suggestions
Read More
Know when to discard an outlier data point in HPLC by using the Q Test - How To
Read More
L3 Linearity Solution Useful for UV Wavelength Accuracy - Tech Information
Read More
LCMS Challenges with HILIC Mobile Phases from Salt Buildup and Ion Suppression Explained - Tips & Suggestions
Read More
LFER Studies Compared to Log D Data in Describing the Aqueous Normal Phase ANP Retention - Tips & Suggestions
Read More
Limited Volume Vial Selection Suggestions - Tips and Suggestions
Read More
Litchi Seed Extracts Analyzed by LCMS - AppNote
Read More
LOQ and LOD Differences Between Instruments - Tech Information
Read More
Low pH buffers Used to Separate Acidic Compounds in RP - HPLC Primer
Read More
Low Volume Sample Study of Proteins Recommendation - Tech Information
Read More
Lower Retention When Functional Group in a Compound Should be Ionized - Troubleshooting Tips
Read More
Maximum Pressure Cogent HPLC Columns Can Tolerate - Tech Information
Read More
Maximum recommended flow rates for the different filter pore sizes. – Tech Information
Read More
Measure signal to noise ratio in an HPLC chromatogram - How to
Read More
Metal Content Affects Silica Particle and Contributes to Peak Shape - Tech Information
Read More
Method Development Advice for Using a TYPE-C HPLC Column - Tips and Suggestions
Read More
Method Development for Polar Compound with TYPE-C Columns - Tips and Suggestions
Read More
Method Development of Maleic Hydrazide - Tips & Suggestions
Read More
Minimize HPLC Column Blockage from Most Common Causes - Tips & Suggestions
Read More
Missing peaks using UV detection in HPLC methods - Tech Information
Read More
My retention times are changing after storing my buffer and what could be causing this and tips to help avoid issues - FAQ
Read More
Negative Baselines Observed in HPLC Runs at 214 nm - Tips & Suggestions
Read More
No Peaks for Succinic Acid or Alpha-kKtoglutarate With the Cogent Diamond Hydride LCMS Column - Tips & Suggestions
Read More
Not Seeing an Expected Peak in an HPLC Assay - Tips & Suggestions
Read More
Obtain a flat baseline in a gradient method without using blank subtraction - How to
Read More
Optimizing Separation of Polar and Non‑Polar Analytes Using Cogent TYPE‑C Silica™ Columns - Tech Information
Read More
Peak area decreases with increasing flow rate - FAQ
Read More
Percentage of acid needed in Aqueous Normal Phase ANP methods - Tips & Suggestions
Read More
Phospholipid Separations by HPLC - Tips & Suggestions
Read More
Phospholipids Analyzed with LCMS - AppNote
Read More
Polar and Mixed‑Polarity Metabolites Strategy Using Panel Method Cogent Diamond Hydride - Tips and Suggestions
Read More
Polar Compounds are Not Well Retained by Reversed Phase Columns Explained - HPLC Primer
Read More
Polypropylene Vial PFAS Analysis Using Glass or Plastic - Tips and Suggestions
Read More
Poor HPLC peak shape can be due to injection sample mismatch - Tips & Suggestions
Read More
Positional Isomer Separation Method Suggestions using HPLC or LCMS - Tips & Suggestions
Read More
Positive Ion Mode LCMS Retention of Polar Compounds - Tips and Suggestions
Read More
Positive or Negative ion mode Salt Suggestions for LC-MS Method Development - Tips & Sugeestions
Read More
Post Time Term Used in an LCMS or HPLC Gradient Method Defined - HPLC Primer
Read More
Pre mix your diluent and mobile phase in sample preparation for HPLC - Tips & Suggestions
Read More
Pre Slit Septa in Autosampler Vial Cap - Purpose - HPLC Primer
Read More
Precision and Suitability of the Cogent TYPE-C HPLC Columns in LCMS - Tech Information
Read More
Precision in Analytical Analysis Definition Made Easy - PRIMER
Read More
Prepare a 16mM Ammonium Acetate Buffer 90:10 in Acetonitrile for HPLC - Tips & Suggestions
Read More
Pressure Expected When Using a Diamond Hydride 2.o UHPLC Column - Tech Information
Read More
Purge metals from HPLC system using EDTA - How To
Read More
Qualification Kits Use with Most HPLC Instruments - Tech Information
Read More
Quaternary Amines Analysis by LCMS Finding the Right Ion - Tech Information
Read More
Random shifting of retention times in HPLC chromatograms - Tips & Suggestions
Read More
Recover an HPLC Column That Has Had Ammonium Acetate Precipitated In It - Troubleshooting
Read More
Reduce the Need to Clean or Wash HPLC Columns - Guidelines - Tips and Suggestions
Read More
Remove a Ferrule That is Stuck in an HPLC System or Column - Tips & Suggestions
Read More
Rescaling Graphs in the HPLC Qualification Kit Excel Template - Tips and Suggestions
Read More
Response Improvement in Your HPLC UV Detector - Tips and Suggestions
Read More
Restoring the Initial Method Results Analyzing AMP ADP ATP UDP and GPT in Biological Extracts - Troubleshooting
Read More
Retention And or Peak Shape for Citric Acid has Changed Compared to Data from a Previous HPLC Run - Tips & Suggestions
Read More
Retention Decrease as Mobile Phase Water Content Increases on a Cogent Bidentate C18 Column - Troubleshooting
Read More
Retention Times Vary from Instrument to Instrument - Tech Information
Read More
Ribose and Xylose analysis without forming Schiff bases - AppNote
Read More
RSA-Pro X Autosampler Vial Improves Quantitation Precision – AppNote
Read More
Sample Carry Over Using One Syringe Filter for Many Samples - FAQ
Read More
Sample concentration changes can effect retention time in HPLC - Primer
Read More
Sample Diluents Should Match Your Starting Mobile Phase - Tips & Suggestions
Read More
Saw Tooth Pattern in the UV Baseline - Troubleshooting
Read More
Screw Thread Call Out Definition - Tech Information
Read More
Selectivity Modification in an ANP Method Using Different Mobile Phase pH - Tips & Suggestions
Read More
Serum Samples Use Suggestion for Cogent Diamond Hydride Columns in LCMS Methods - Tips & Suggestions
Read More
Should I Filter my HPLC Solvents and Buffers before Use - FAQ
Read More
Should I use a 1 piece fitting or a 2 piece fitting for HPLC - FAQ
Read More
Should I use methanol as the organic solvent in HPLC when using Aqueous Normal Phase ANP - FAQ
Read More
Silicone Rubber Purity Used in Septa for Autosampler Vial Septa - Tech Information
Read More
Simple Sugars Methods using Triethylamine TEA in Aqueous Normal Phase ANP Methods - Tips & Suggestions
Read More
Since Cogent TYPE-C columns can be used in Reversed Phase or Normal Phase what do you suggest to switch these solvent systems which are not miscible - FAQ
Read More
Sodium Ion Interference in ANP Methods: Challenges in Analyzing Sodium Succinate - Tips & Suggestions
Read More
Storage and Condition Guide for Cogent TYPE-C HPLC Columns - Tech Information
Read More
Storing Cogent Diamond Hydride HPLC Columns - Tech Information
Read More
Storing the Chemical Solutions Qualification Kit Solutions When Not in Use - How To
Read More
Suggestion for separation of phenylephrine HCl acetaminophen and dextromethorphan - Tips & Suggestions
Read More
Tandem HPLC Columns in One Separation for Polar and Non Polar Compounds - Tips and Suggestions
Read More
Tartaric and Malic Acid Separation in a Complex Mixture - AppNote
Read More
Techniques to prepare a 0.05% solution from a tablet for HPLC injection - How to
Read More
Temperature Changes for Separations of Terpenoids - Tips & Suggestions
Read More
Temperature Range Maximum for Cogent Diamond Hydride HPLC Columns - Tech Information
Read More
Temperature Range of MICROSOLV Brand Autosampler Vial Screw Caps - Tech Information
Read More
The effect of ionic strength of the mobile phase additive for HPLC columns in Aqueous Normal Phase - Tips & Suggestions
Read More
Theoretical Plate Estimates Indicates Column Condition - HPLC Primer
Read More
Tip for working with plasma samples and Cogent TYPE-C HPLC columns - Tips & Suggestions
Read More
Tizanidine HCl HPLC Method Transferred to Near UHPLC - AppNote
Read More
To obtain greater sensitivity than Na adducts for sugars could you add ammonia NH4 instead - FAQ
Read More
Troubleshooting Problems With Poor HPLC Results Before Examining the Column - Tips & Suggestions
Read More
Two Peaks for Quaternium-15 or Dowicil-75 in LCMS Data - Tech Information
Read More
Use a linear flow rate test to check back pressure on an HPLC column - Tech Information
Read More
Use Bubble Point to Filter Water Through Hydrophobic Membranes - HPLC Primer
Read More
Use Teflon bottles for A and B solvents in negative ion mode LCMS - HPLC Primer
Read More
Using a Constant Pressure Method on two Instruments Producing Different Flow Rates- Tips & Suggestions
Read More
Using Ammonium Acetate or Ammonium Formate in Diamond Hydride Methods - Tips & Suggestions
Read More
Using methanol instead of acetonitrile in an HPLC method should be done with caution - Tips & Suggestions
Read More
Validating HPLC and LC-MS Methods for Regulated Labs - Primer
Read More
Vials Listed as 12 x 32 mm Compatibility with Autosamplers' Maximum Diameter of 11.8 mm - HPLC Primer
Read More
What are some common sources of variance during sample preparation in an analytical application - FAQ
Read More
What are the Temperature and Pressure Limits for Amber Glass Autosampler Vials - Tech Information
Read More
What are the typical flow rates recommended by HPLC column companies to start with for various column ID - Primer
Read More
What can Cause Changing Analyte Recovery in HPLC - FAQ
Read More
What can cause changing retention times and a peak showing up in my blank with a Silica-C column - FAQ
Read More
What effect does high injection volume have on column performance in Aqueous Normal Phase ANP HPLC- FAQ
Read More
What inside diameter ID of standard tubing is most suitable for HPLC mobile phase - FAQ
Read More
What is a Master Batch for Cogent HPLC Columns - FAQ
Read More
What is the effect of extra column volume for different HPLC instruments on the same method - FAQ
Read More
What is the Functional Difference Between the MRQ and the Max Recovery Autosampler Vials - HPLC Primer
Read More
What is the maximum concentration of ammonium fluoride to use in a mobile phase to avoid column damage - Tips & Suggestions
Read More
What is the maximum loading capacity mass injection volume that can be used for a semi prep Cogent TYPE-C HPLC column - FAQ
Read More
What is the maximum pressure rating for Cogent HPLC columns? - FAQ
Read More
What is the maximum salt concentration to use with Cogent TYPE-C HPLC columns with HPLC or LCMS - FAQ
Read More
What is the purpose of using isopropanol IPA as part of the mobile phase solvent in ANP methods - FAQ
Read More
What type of fittings can I use in mobile phase connections - FAQ
Read More
What type of tubing do I use to connect the guard column holder to analytical columns - FAQ
Read More
What will the pressure be with a mobile phase of 90% methanol and 10% DI water with a 4.6 x 250mm Cogent TYPE-C HPLC column - FAQ
Read More
When I run gradients on my HPLC and switch from one gradient to another my baseline shows as negative and if I auto zero it becomes positive for the remainder of the run but when I start again it is negative - Primer
Read More
When to Use PEEK or Stainless Steel for HPLC Column Hardware - Tips & Suggestions
Read More
Which Syringe Filter Membrane is Best for Aqueous Buffers - FAQ
Read More
White Film on an LCMS Source with Background Noise was Very Low - Tech Information
Read More
Why am I observing broad split peaks in Aqueous Normal Phase ANP when using acetonitrile and methanol diluents - FAQ
Read More
Why am I seeing multiple peaks in HPLC runs of fructose - Tips & Suggestions
Read More
Why am I seeing two peaks for quaternium15 Dowicil-75 in LCMS - FAQ
Read More
Why are ionized polar compounds generally better retained in Aqueous Normal Phase ANP HPLC - FAQ
Read More
Why are the Cogent Silica-C columns more stable than other silica columns - FAQ
Read More
Why do I have higher pressure at a lower flow rate in my HPLC runs - FAQ
Read More
Why do I see large intermittent pressure spikes in HPLC runs and can it be a defective column - FAQ
Read More
Why is isopropanol rarely used as a solvent in HPLC or LCMS methods - FAQ
Read More
Why you should use temperature control with the UDC-Cholesterol column - Tips & Suggestions
Read More
Will a different guard column hardware system different from the Cogent system affect my results when using a Cogent column - FAQ
Read More
Will I Protect HPLC Columns from Samples that Get Permanently Adsorbed by Using a Syringe Filter - FAQ
Read More
Will phosphates precipitate in an HPLC column - PRIMER
Read More